SPECIFICATIONS
|
|
| Connector: |
Terminal block #1
Phoenix Contact MSTB series
5 position two part terminal block
Model: MSTB 2,5/5-ST-5,08
Order number: 17 57 04 8
|
Terminal block #2
Phoenix Contact MSTB series
3 position two part terminal block
Model: MSTB 2,3-G-5,08
Order number: 17 55 74 9 |
| Connector pin out: |
Terminal Block #1 (DMX512 Output)
1 (C) DMX512 common
2 ( -) DMX512 data -
3 (+) DMX512 data +
4 (C) Supply common
(internally tied to pin1)
5 (V) Supply voltage "hot"
|
Terminal Block #2 (DMX512 Input)
1 (C) DMX512 common
2 ( -) DMX512 data -
3 (+) DMX512 data + |
| Input circuit: |
ESD protected EIA-485 transceiver (LT1785)
|
| Output circuit: |
ESD protected EIA-485 transceiver (LT1785)
|
| Isolation: |
None. DMX input is not isolated from DMX output. |
| Indicators: |
Ten green SHOW LEDs
One green PAUSE LED
One green LOOP LED
One yellow START LED
One yellow END LED
One red INPUT/RECORD LED
|
| User controls: |
Ten [SHOW] buttons
One [PAUSE] button
One [LOOP] button
One [REWIND] button
One [FORWARD] button
One recessed [RECORD] button
|
| Option jumpers: |
|
INSTALLED |
REMOVED |
| JP1 |
Recording enabled |
Recording/editing disabled |
| JP2 |
Run show on DMX512 loss |
Hold last look on DMX512 loss |
| JP3 |
Normal operation |
Run hardware test |
| JP4 |
Normal operation |
Disable operation |
| JP5 |
Unused |
Unused |
| JP6 |
Normal operation |
Erase Memory (DANGER!) |
|
| Power input: |
9 to 15 volts DC or 8 to 24 volts AC / 150mA per station
(A 10 volt class 2 "doorbell" transformer is recommended for fixed installations)
|
| Color: |
Black anodized, with silver engraved nomenclature |
| Size : |
Faceplate: 4.5"h X 4.6"w X 0.2"d
Faceplate rear inset: 4.15"h X 4.25"w X 0.1"d
Electrical box minimum inside dimensions: 2.9"h X 3.5"w X 1.5"d
|