![]() |
![]() |
![]() |
||
Basic Specification
|
|||||||||||||||||||||||||||||||||||||||
|
Input module
|
|
| Input circuit: | EIA-485 receiver with 120 ohm termination resistor between +Data and -Data. |
| Input connectors: | Gold plated 5 pin male Neutrik D-1 series (3 pin or terminal connections are optional). |
| Output circuit: | EIA-485 transmitter with 60 ohm series (source) termination (DMX512 signals on a non-standard connector). |
| Output connector: | DB-25P.(male) |
|
Output module
|
|
| Input circuit: | EIA-485 receiver. A termination plug is required if the output module is separated from the input module by more than six feet. |
| Input connector: | DB-25P (male) |
| Output circuit: | EIA-485 transmitter
NOTE: This product uses a slew-rate-limited output drivers. Slew-rate-limited drivers minimize EMI and reduce reflections caused by improperly terminated cables. |
| Output connectors: | Gold plated 5 pin female Neutrik D-1 series (3 pin or terminal connections are optional) |
|
DB-25 pinouts
|
|
| input #: | 1 2 3 4 5 6 7 8 9 10 11 12 |
| data - pin #: | 14 15 16 17 18 19 20 21 22 23 24 25 |
| data + pin #: | 2 3 4 5 6 7 8 9 10 11 12 13 |
| pin 1 is circuit common |
|
|
Common specifications
|
|
| Isolation: | 2500 volt optical coupler, 1500 volt split bobbin transformer |
| Power input: | 100 - 120 volts, 50/60 hertz, 12 watts (208 - 240 volt optional) |
| Size & weight: | 1.74" high, 19" wide, 12" deep, 9 pounds (19" rack adapter is provided). |