| Input circuit: |
EIA-485 receiver with series self resetting fuses (PTC) and transient absorbing diodes. |
| Input protection: |
Not damaged by continuous 120VAC line cross or up to 5KV transients. |
| Input isolation: |
750 volt DC/DC converter, 2500 volt optical coupler. |
| Input termination: |
120 ohm termination circuit may be switched in or out via external jumper |
| Input signal: |
0.2 volts minimum, 12 volts maximum |
| Output circuit: |
EIA-485 driver with self resetting fuses and transient absorbing diodes. |
| Output protections: |
Not damaged by continuous 120VAC line cross or up to 15KV transients.
|
| Wire size: |
24-14 AWG |
| Connector: |
Phoenix Contact MSTB series 12 position. |
|
Supplied male header: Phoenix part number MSTBA2,5/12-G-5,08 |
|
Supplied mating female connector: Phoenix order number 1757116 |
|
|
| Connector pin outs: |
1 - DMX512 common (tied to pin 7)
2 - DMX512 data -
3 - DMX512 data +
4/5 - Jumper together to terminate DMX512 input with 120 ohms
6 - no connection
7 - common DC supply (12 - 24 VDC) (tied to pin 1)
8 - positive DC supply (12 - 24 VDC)
9 - no connection
10 - isolated DMX512 tap common
11 - isolated DMX512 tap data-
12 - isolated DMX512 tap data+
|
| Power input: |
12 to 24 Volts DC, 0.3 Amps |
| Color: |
Phoenix Contact green |
| DIN-rail: |
15 mm wide top-hat rail (EN 50045, BS 6273)
33 mm G-type rail (EN 50035, BS 5825).
35 mm wide top-hat rail (EN 50022, BS 5584)
|
| Size: |