Basic Specification
|
| Input signal: | 250 Kilobaud (CMX's 153.6 Kilobaud is optional) 0.2 volts minimum, 12 volts maximum |
| Input circuit: |
EIA-485 receiver with 22 K-Ohm pull up on +Data 22 K-Ohm pull down on -Data |
| Input connector: | Gold plated 5 pin male (Neutrik D-1 series) |
| Input pass through: | Gold plated 5 pin female (Neutrik D-1 series) All five pins are passed through |
| Output signal: |
Data clock: 8 uS (micro seconds) |
| Output circuit: |
Clock: EIA-485 driver |
| Output connector(s): | Gold plated 4 pin male (Neutrik D-1 series) |
| Output Pinout: | Pin Function 1 COMMON 2 CLOCK+ 3 ANALOG DATA 4 CLOCK- |
| Power input: | 100 - 120 volts, 50/60 hertz, 12 watts (208 - 240 volt optional) |
| Color: | Black front, back, top, and sides. Clear iridite aluminum bottom. |
| Size and weight: | 9" deep, 1.6" high, 5.6" wide, 2.5 pounds (19" rack adapter available) |