Basic Specification
|
| Input signal: | 250 Kilobaud, 0.2 volts minimum, 12 volts maximum. |
| Input circuit: | EIA-485 receiver with two 100 ohm PTC self resetting fuses, four low capacitance transient suppression diodes. |
| Input connector: | Gold plated 5 pin male (Neutrik D-1 series). |
| Input pass through: | Gold plated 5 pin female (Neutrik D-1 series). All five pins are passed through. |
| Power input: | 120 - 240 volts, 50/60 hertz, 2 watts (plus load). |
| Power input plug: | NEMA type 5-15P dead front plug standard, others optional. |
| Power output: | Input power is switched to output. (Hot side only) |
| Power output socket: | NEMA type 5-15R dead front receptacle standard, others optional. |
| Output rating: | 15 amps with standard connectors, 20 amps with optional connectors. |
| Output device: | Omron G8P. |
| Mechanical life: | 10,000,000 operations minimum. |
| Electrical life: | 250,000 operations minimum at 5 Amps. 125,000 operations minimum at 20 Amps. |
| Color: | Top, bottom and sides: Silver hammer tone. Front and back: Black. |
| Size and weight: | 6.5" deep, 1.7" high, 6.5" wide, 2.7 pounds (19" rack adapter available). |
| Warranty: | Five years on defects in manufacturing. Output device is not covered. |